- After-sale Service: Online technical support
- Brand Name: CONTEC
- Model Number: CMS8500
- Power Source: Electricity
- Material: Plastic
- Quality Certification: ce
- Instrument classification: Class II
- Safety standard: None
- Type: patient monitor
- Single package size:: 50X50X50 cm
- Single gross weight:: 13.000 kg
The monitor boasts a plethora of functions suitable for clinical monitoring of adults, pediatrics, and neonates. Users have the ability to select parameter configurations tailored to specific requirements. Powered by 100V-240V~, 50Hz/60Hz, the monitor is equipped with a 14″ color TFT LCD display presenting real-time data and waveforms. The device can simultaneously display ten-channel waveforms and complete monitoring parameters while offering an optional 48mm thermal recorder. Additionally, the monitor can be wirelessly or wiredly connected to a central monitoring system to form a network monitoring system.
This apparatus can monitor vital parameters, including ECG, RESP, NIBP, SpO₂, and dual-channel TEMP, among others. The parameter measurement module, display, and recorder are integrated into a single, compact, and portable device. Furthermore, its replaceable internal battery brings a great deal of convenience for patient mobility.
Function:
14″ high-definition touch screen design, easy and convenient to operate, elegant and concise in appearance.
Independent physiological and technical alarm function, convenient for medical staff to quickly know patient’s condition.
Adopt high-performance processor, stable, reliable and fast to process information.
Patient information can be rapidly entered, patient type (adult/neonate/pediatric) can be quickly switched, meets the requirements of different departments.
Abundant analysis functions: 23 arrhythmia, full-lead ST-segment and pacing analysis; multiple calculation functions (such as calculation of drug concentration, titration table, hemodynamics, ventilation, oxygenation, renal function, etc.).
With the functions of waveform freezing, holographic waveform storage and review.
Automatic data storage in case of power failure.
Built-in large-capacity detachable lithium battery, ensures uninterrupted monitoring.
Fanless design, ensures no noise and low power consumption during working.
Connect to Central Monitoring System developed by our company by WiFi/Wired, convenient to transmit patient’s real-time information by mode, be applied to clinical monitoring, avoids affecting patient’s rest, one-button switching, reduces the workload of medical staff.
Performance:
ECG
Lead type:
3-lead: I, II, II
5-lead: l, II, Il, aVR, aVL, aVF, V
12-lead: l, ll, Il, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
HR
Measurement and alarm range:
Adult: 15~300 bpm
Pediatric/neonate: 15~350 bpm
Resolution: 1 bpm
Accuracy: ±1% or ±1bpm, whicheveris greater.
ST-segment detection
Measurement and alarm range: -2.0mV~+2.0 mV
Accuracy: -0.8mV~+0.8mV: ±0.04mV or ±10%, whicheveris greater.
Other range: unspecified
Arrhythmia analysis: 23 kinds
Pacemaker: yes
RESP
Measurement mode: impedance
Respiration rate:
Measurement range: 0 rpm~150 rpm
Resolution: 1 rpm
Accuracy: 7~150 rpm, ±2rpm or±2%, whicheveris greater;
0~6 rpm, unspecified
Apnea alarm: 10~60s.
Scan speed: 6.25mm/s, 12.5 mm/s, 25mm/s, 50mm/s.
NIBP
Measurement mode: Oscillometry
Working mode: Manual/AUTO/Continuous/Order
Measurementinterval in AUTO mode: 1 min, 2 min, 2.5 min, 3 min,
5 min, 10 min, 15 min, 20min, 30min, 1h, 1.5h, 2h, 3h, 4h, 8h
Measurement period in Continuous mode: 5 minutes
Static pressure Measurement range: 0mmHg~300 mmHg (0.0kPa~40kPa)
Resolution: 1mmHg
Cuff pressure accuracy: ±3mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297±3mmHg
Pediatric mode: 260±3 mmHg
Neonatal mode: 147±3mmHg
SpO₂
Measurement range: 0%~100 %
Resolution: 1%
Accuracy: 70%~100%, ±2%;0%~69%, unspecified
PR
Measurement and alarm range: 25~250 bpm
Accuracy: ±2 bpm or±2%, whicheveris greater.
TEMP
Channel: dual-channel
Measurement range: 0~50℃
Resolution: 0.1℃
Accuracy: ±0.1℃
CO₂
Measurement mode: mainstream or sidestream
CO₂ measurement range: 0~150 mmHg
Accuracy:
0~40mmHg: ±2mmHg;
41~70mmHg: ±5%;
71~100mmHg: ±8%;
101~150mmHg: ±10%
AwRR measurement range:
Sidestream: 2~120 rpm;
Mainstream: 2~150 rpm.
AwRR accuracy: ±1rpm
Apnea alarm: yes
IBP
Channel: 2-channel (Expandable 4-channel)
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measurement and alarm range: -50~300 mmHg.
Resolution: 1mmHg.
Accuracy: ±2% or 1 mmHg, whicheveris greater.
Power supply: 100V-240V~50Hz/60 Hz.
Safety class: classl, defibrillation-proof type CF applied part.
Waterproof degree: IPX2.